banner



Concrete Flat Roof Detail Drawings

Detail 90930-011

snow stop

snow stop profile

Categories: Mounting parts, Snow guard

Detail 60510-011

Inner gutter / warm roof

Inner gutter in a warm roof

Categories: Drainage, Internal drainage, with gutters

Detail 6-1b

Roof edge / warm roof

Roof edge trim profile T plus, TA, TAG and art-line.

Categories: Roof edge, without abutment

Detail 50533-711

passive house / roof window

roof window for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 6-2a

Roof edge / inverted roof

Roof edge trim profile

Categories: Roof edge, without abutment

Detail 6-3a

Roof edge / cold roof

Roof edge trim profile

Categories: Roof edge, without abutment

Detail 7-1a

Roof edge / warm roof

Roof edge trim profile

Categories: Roof edge, without abutment

Detail 7-2a

Roof edge / inverted roof

Roof edge trim profile

Categories: Roof edge, without abutment

Detail 5-1Aa

Attic / warm roof

Roof edge trim profile

Categories: Roof edge, with abutment (attic)

Detail 5-1a

Attic / warm roof

Wall capping profile

Categories: Roof edge, with abutment (attic)

Detail 5-2a

Attic / inverted roof

Wall capping profile

Categories: Roof edge, with abutment (attic)

Flachdachatlas Detail 7-3a

Roof edge / cold roof

Roof edge trim profile

Categories: Roof edge, without abutment

Detail 18-2a

DIN18234 / roof edge

DIN 18234 – roof edge

Categories: DIN 18234 (industry construction standard), Roof edge

Detail 80511-911

vent / DIN18234

DIN 18234 – vent with fire guard

Categories: DIN 18234 (industry construction standard), Small penetration

Detail 70541-911

emergency drainage / DIN18234

DIN 18234 – emergency drainage with fire guard

Categories: DIN 18234 (industry construction standard), Small penetration

Detail 70511-911

outlet / DIN18234

DIN 18234 – outlet with fire guard

Categories: DIN 18234 (industry construction standard), Small penetration

Detail 18-1e

DIN18234 / penetration

DIN 18234 – penetrations

Categories: DIN 18234 (industry construction standard), Mid-size/large penetration

Detail 18-2b

DIN18234 / connection

DIN 18234 – connection on rooflight

Categories: DIN 18234 (industry construction standard), Mid-size/large penetration

Detail 10210-931

EVALASTIC V / DIN 18234

DIN 18234 – EVALASTIC V on insulation and trapezoidal steel sheet profile ballasted.

Categories: DIN 18234 (industry construction standard), Layer structure

Detail 10210-921

EVALASTIC V / DIN 18234

DIN 18234 – EVALASTIC V on insulation, mechanically fastened in trapezoidal metal sheet.

Categories: DIN 18234 (industry construction standard), Layer structure

Detail 10210-911

EVALASTIC V / DIN 18234

DIN 18234 – EVALASTIC V bonded on insulation.

Categories: DIN 18234 (industry construction standard), Layer structure

Detail 10130-911

EVALON VSK / DIN 18234

DIN 18234 – EVALON VSK bonded on insulation, supporting substructure trapezoidal steel sheet profile.

Categories: DIN 18234 (industry construction standard), Layer structure

Detail 10110-931

EVALON V / DIN 18234

DIN 18234 – EVALON V on insulation and trapezoidal steel sheet profile ballasted.

Categories: DIN 18234 (industry construction standard), Layer structure

Detail 10110-911

EVALON V / DIN 18234

DIN 18234 – EVALON V bonded on insulation.

Categories: DIN 18234 (industry construction standard), Layer structure

Detail 18-2c

DIN18234 / dilatation joint

DIN 18234 – movable wall flashing

Categories: DIN 18234 (industry construction standard), Wall flashing/expansion joint

Detail 14-2a

Fall protection / inverted roof

waterproofing of a fall protection

Categories: Fall protection, Mounting parts

Detail 14-3a

Fall protection / cold roof

waterproofing of a fall protection

Categories: Fall protection, Mounting parts

Detail 14-1a

Fall protection / warm roof

waterproofing of a fall protection

Categories: Fall protection, Mounting parts

Detail 10580-035

Fall protection / warm roof

warterproofing of a fall protection

Categories: Fall protection, Mounting parts

Detail 10585-111

dilatation joint / concrete (type I)

formation of dilatation joints type I in warm deck roof.

Categories: Expansion joint, General details, Mounting parts

Detail 10585-021

dilatation joint / trapezoidal metal sheet (type I)

formation of dilatation joints type I in warm deck roof.

Categories: Expansion joint, General details, Mounting parts

Detail 10585-131

dilatation joint / concrete (type II)

formation of dilatation joints type II in warm deck roof.

Categories: Expansion joint, General details, Mounting parts

Detail 10585-121

dilatation joint / trapezoidal metal sheet (type II)

formation of dilatation joints type II in warm deck roof.

Categories: Expansion joint, General details, Mounting parts

Detail 10585-111

dilatation joint / concrete (type II)

formation of dilatation joints type II in warm deck roof.

Categories: Expansion joint, General details, Mounting parts

Detail 17-1c

Dilatation joint / warm roof

Dilatation joint, separation and roof valley fixation

Categories: Expansion joint, General details, Mounting parts

Detail 17-2c

Dilatation joint / inverted roof

Dilatation joint (type II) in inverted roofs

Categories: Expansion joint, General details, Mounting parts

Detail 17-3b

Dilatation joint / cold roof

Dilatation joint (type II) in cold roofs

Categories: Expansion joint, General details, Mounting parts

Detail 10590-221

fixation of valleys / metal sheet

fixation of valleys mit metal sheet

Categories: Fixation of valleys, General details, Mounting parts

Detail 10590-211

fixation of valleys / single fasteners

fixation of valleys mit single fastenersn

Categories: Fixation of valleys, General details, Mounting parts

Detail 50533-011

Brakel GreenLite / flange adapter

Brakel GreenLite with flange adapter

Categories: Mounting parts, Rooflights/NRA

Detail 50532-011

3020 / Brakel GreenLite

upstand 3020 and roof light Brakel GreenLite.

Categories: Mounting parts, Rooflights/NRA

50522-011

3020 / window

upstand 3020 and roofligt window

Categories: Mounting parts, Rooflights/NRA

Detail 50512-111

3020 ventilated

upstand 3020 and roof light.

Categories: Mounting parts, Rooflights/NRA

Detail 50512-011

3020 rigid

upstand 3020 and roof light.

Categories: Mounting parts, Rooflights/NRA

Detail 5031-011

1620 / Brakel GreenLite

upstand 1620 and roof light Brakel GreenLite.

Categories: Mounting parts, Rooflights/NRA

Detail 50521-011

1620 / window

upstand 1620 and rooflight window

Categories: Mounting parts, Rooflights/NRA

Detail 50511-111

1620 ventilated

upstand 1620 and roof light.

Categories: Mounting parts, Rooflights/NRA

Detail 50511-011

1620 rigid

upstand 1620 and roof light.

Categories: Mounting parts, Rooflights/NRA

Cover Detail 50530-011

1600 / Brakel GreenLite

upstand 1600 and roof light Brakel GreenLite.

Categories: Mounting parts, Rooflights/NRA

Detail 50520-011

1600 / window

upstand 1600 and rooflight window

Categories: Mounting parts, Rooflights/NRA

Detail 50510-111

1600 ventilated

upstand 1600 and roof light.

Categories: Mounting parts, Rooflights/NRA

Detail 50510-011

1600 rigid

upstand 1600 and roof light.

Categories: Mounting parts, Rooflights/NRA

Detail 80520-111

Refurbishment vent / cold roof

Refurbishment vent, one-piece

Categories: Mounting parts, Vents

Detail 80520-011

Refurbishment vent / warm roof

Refurbishment vent, one-piece

Categories: Mounting parts, Vents

Cold roof vent / timber

cold roof vent for ventilation of a roof spacing

Categories: Mounting parts, Vents

Detail 80511-211

Vent stack / inverted roof

Vent stack

Categories: Mounting parts, Vents

Detail 80511-111

Vent stack / cold roof

Vent stack

Categories: Mounting parts, Vents

Detail 80511-011

Vent stack / warm roof

Vent stack

Categories: Mounting parts, Vents

Detail 11-2c

Drainage / inverted roof

Outer gutter

Categories: Connection to external gutter, Drainage

Detail 11-3a

Drainage / cold roof

Outer gutter

Categories: Connection to external gutter, Drainage

Detail 11-1a

Drainage / warm roof

Outer gutter

Categories: Connection to external gutter, Drainage

Detail 60220-011

Outer gutter / EVALASTIC with ballast

Outer gutter

Categories: Connection to external gutter, Drainage

Detail 60120-011

Outer gutter / EVALON with ballast

Outer gutter

Categories: Connection to external gutter, Drainage

Detail 60520-011

Outer Gutter

Outer gutter

Categories: Connection to external gutter, Drainage

Detail 70517-211

Rainwater outlet horizontal / inverted roof

Horizontal rainwater outlet DN 125 in inverted roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70517-011

Rainwater outlet horizontal / cold roof

Horizontal rainwater outlet DN 125 in cold roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70516-211

Rainwater outlet horizontal / inverted roof

Horizontal rainwater outlets DN 70 and DN 100 in inverted roofs.

Categories: Drainage, Internal drainage, with escapes

Detail 70551-211

Terrace grate / inverted roof

Vertical terrace grates in inverted roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70511-211

Rainwater outlet vertical / inverted roof

Vertical rainwater outlets on inverted roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70516-011

Rainwater outlet horizontal / cold roof

Horizontal rainwater outlets DN 70 and DN 100 in cold roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70511-011

Rainwater outlet vertical / cold roof

Vertical rainwater outlets in cold roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70531-011

Refurbishment rainwater outlet / warm roof

Refurbishment outlet im warm roof constructions.

Categories: Drainage, Internal drainage, with escapes

Detail 70516-111

Rainwater outlet horizontal / warm roof

Horizontal rainwater outlets DN 70 and DN 100 in warm roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70517-111

Rainwater outlet horizontal / warm roof

Horizontal rainwater outlets DN 125 in warm roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70551-111

Terrace grate / warm roof

Vertical terrace grates in warm roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70511-111

Rainwater outlet vertical / warm roof

Vertical rainwater outlets in warm roofs

Categories: Drainage, Internal drainage, with escapes

Detail 70170-011

Water spout VF

Water spout with EVALON connection.

Categories: Drainage, Emergency drainage

Detail 70180-011

Water spout SW rectangular / attic

Water spout with EVALON connection.

Categories: Drainage, Emergency drainage

Detail 70160-011

Water spout SF rectangular / attic

Water spout with EVALON connection

Categories: Drainage, Emergency drainage

Detail 70165-011

Water spout SF round / isolated attic

Water spout with EVALON connection

Categories: Drainage, Emergency drainage

Detail 70165-021

Water spout SF round / unisolated attic

Water spout with EVALON connection

Categories: Drainage, Emergency drainage

Detail 70185-011

Water spout S / attic

Water spout with EVALON connection.

Categories: Drainage, Emergency drainage

Detail 70547-211

Emergency outlet horizontal / inverted roof

Horizontal emergency outlets DN 125 on inverted roofs

Categories: Drainage, Emergency drainage

Detail 70547-211

Emergency outlet horizontal / inverted roof

Horizontal emergency outlets DN 125 on inverted roofs

Categories: Drainage, Emergency drainage

Detail 70546-211

Emergency outlet horizontal / inverted roof

Horizontal emergency outlets DN 70 or DN 100 in inverted roofs

Categories: Drainage, Emergency drainage

Detail 70541-211

Emergency outlet vertical / inverted roof

Vertical emergency outlets in inverted roofs

Categories: Drainage, Emergency drainage

Detail 70547-011

Emergency outlet horizontal / cold roof

Horizontal emergency outlets DN 70 or DN 100 in cold roofs.

Categories: Drainage, Emergency drainage

Detail 70546-011

Emergency outlet horizontal / cold roof

Horizontal emergency outlets DN 70 or DN 100 in cold roofs.

Categories: Drainage, Emergency drainage

Detail 70541-011

Emergency outlet vertical / cold roof

Vertical emergency outlets in cold roofs

Categories: Drainage, Emergency drainage

Detail 70547-111

Emergency outlet horizontal / warm roof

Horizontal emergency outlets DN 125 in warm roofs

Categories: Drainage, Emergency drainage

Detail 70546-111

Emergency outlet horizontal / warm roof

Horizontal emergency outlets DN 70 or DN 100 in warm roofs.

Categories: Drainage, Emergency drainage

Detail 70541-111

Emergency outlet vertical / warm roof

Vertical emergency outlets in warm roofs

Categories: Drainage, Emergency drainage

Detail 60520-711

passive house / roof gutter

roof gutter for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 40925-711

passive house / wall flashing used

wall flashing for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 40920-711

passive house / wall flashing unused

wall flashing for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 20930-711

passive house / roof edge

attic and roof edge for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 10110-713

roof build-up / used

roof build-up for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 10110-711

passive house / roof build-up ballasted

roof build-ups for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 10110-715

passive house / roof build-up adhered

roof build-ups for passive houses

Categories: Passive house (principle sketches), Special constructions

Detail 10210-233

EVALASTIC V / pumice concrete pannels

EVALASTIC V on insulation and pumice pannels ballasted.

Categories: balconies / terraces / roof terraces, Layer structure (membranes), used area

Detail 10210-223

EVALASTIC V / lightweight concrete

EVALASTIC V on insulation and lightweight concrete decking ballasted.

Categories: balconies / terraces / roof terraces, Layer structure (membranes), used area

Detail 10210-213

EVALASTIC V / concrete

EVALASTIC V on insulation and steel concrete decking ballasted.

Categories: balconies / terraces / roof terraces, Layer structure (membranes), used area

Detail 10110-233

EVALON V / pumice concrete pannels

EVALON V on insulation and pumice pannels ballasted.

Categories: balconies / terraces / roof terraces, Layer structure (membranes), used area

Detail 10110-223

EVALON V / lightweight concrete

EVALON V on insulation and lightweight concrete decking ballasted.

Categories: balconies / terraces / roof terraces, Layer structure (membranes), used area

Detail 10110-213

EVALON V / concrete

"EVALON V on insulation and steel concrete decking ballasted."

Categories: balconies / terraces / roof terraces, Layer structure (membranes), used area

Detail 10210-511

EVALASTIC V / timber

EVALASTIC V on timber ballasted.

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, ventilated roof (cold roof)

Detail 10110-511

EVALON V / timber

EVALON V on timber ballasted.

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, ventilated roof (cold roof)

Detail 10210-411

EVALASTIC V / timber

EVALASTIC V mechanically fastened in timber.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, ventilated roof (cold roof)

Detail 10120-411

EVALON VG / timber

EVALON VG, mechanically fastened in timber.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, ventilated roof (cold roof)

Detail 10120-162

EVALON VG / derived timber product

EVALON VG, mechanically fastened in derived timber pannel.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, ventilated roof (cold roof)

Detail 10120-152

EVALON VG / timber deck

EVALON VG, mechanically fastened in timber deck.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, ventilated roof (cold roof)

EVALASTIC VGSK / derived timber pannel (ballasted)

EVALASTIC VGSK bonded on derived timber product.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10240-312

EVALASTIC VGSK / derived timber product

EVALASTIC VGSK bonded on derived timber pannel.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10140-312

EVALON VGSK / derived timber product

EVALON VGSK bonded on derived timber product.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10210-311

EVALASTIC V / timber

EVALASTIC V bonded on supporting layer, supporting substructure timber.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10130-511

EVALON VSK / timber (ballasted)

EVALON VSK bonded on separation layer, supporting substructure timber.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10130-311

EVALON VSK / timber

EVALON VSK bonded on timber.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10110-311

EVALON V / timber

EVALON V bonded on supporting layer, supporting substructure timber.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10110-061

EVALON V / derived timber product

EVALON V bonded on nailed supporting layer, supporting substructure derived timber pannel.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10110-051

EVALON V / timber deck

EVALON V bonded on supporting layer, supporting substructure timber deck.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10210-061

EVALASTIC V / derived timber product

EVALASTIC V bonded on supporting layer, supporting substructure derived timber pannel.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

EVALON VGSK / derived timber pannel (ballasted)

EVALON VGSK bonded on derived timber product.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10210-051

EVALASTIC V / timber deck

EVALASTIC V bonded on supporting layer, supporting substructure timber deck.

Categories: adhered, Layer structure (membranes), unused roof area, ventilated roof (cold roof)

Detail 10210-861

EVALASTIC V / derived timber product

EVALASTIC V on derived timber product under insulation and ballast.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10210-851

EVALASTIC V / timber deck

EVALASTIC V on timber deck under insulation and ballast.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10210-831

EVALASTIC V / pumice concrete pannels

EVALASTIC V on insulation and pumice pannels ballasted.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10210-821

EVALASTIC V / lightweight concrete

EVALASTIC V on insulation and lightweight concrete decking ballasted.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10210-811

EVALASTIC V / concrete

EVALASTIC V on insulation and steel concrete decking ballasted.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10110-861

EVALON V / derived timber product

EVALON V on derived timber product under insulation and ballast.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10110-851

EVALON V / timber deck

EVALON V on timber deck under insulation and ballast.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10110-831

EVALON V / pumice concrete pannels

EVALON V on pumice pannels under insulation and ballast.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10110-821

EVALON V / lightweight concrete

EVALON V on lightweight concrete decking under insulation and ballast

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10110-811

EVALON V / concrete

EVALON V on steel concrete decking under insulation and ballast.

Categories: inverted roof / duo roof / plus roof, Layer structure (membranes), loose laid with ballast, unused roof area

Detail 10210-231

EVALASTIC V / pumice concrete pannels

EVALASTIC V on pumice pannels under insulation and ballast.

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, unventilated roof (warm roof)

Detail 10210.221

EVALASTIC V / lightweight concrete

EVALASTIC V on insulation and lightweight concrete decking ballasted.

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, unventilated roof (warm roof)

Detail 10210-211

EVALASTIC V / concrete

EVALASTIC V on insulation and steel concrete decking ballasted.

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, unventilated roof (warm roof)

Detail 10110-231

EVALON V / pumice concrete pannels

EVALON V on insulation and pumice pannels. ballast (gravel).

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, unventilated roof (warm roof)

Detail 10110-221

EVALON V / lightweight concrete

EVALON V on insulation and lightweight concrete decking ballasted.

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, unventilated roof (warm roof)

Detail 10110-211

EVALON V / concrete

EVALON V on insulation and steel concrete decking ballasted.

Categories: Layer structure (membranes), loose laid with ballast, unused roof area, unventilated roof (warm roof)

Detail 10210-161

EVALASTIC V / derived timber product

EVALASTIC V on insulation, mechanically fastened in derived timber pannel.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10210-151

EVALASTIC V / timber deck

EVALASTIC V on insulation, mechanically fastened in timber deck.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10210-141

EVALASTIC V / trapezoidal metal sheet

EVALASTIC V on insulation, mechanically fastened in trapezoidal steel sheet profile.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10210-131

EVALASTIC V / pumice concrete pannels

EVALASTIC V on insulation, mechanically fastened in pumice pannels.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10210-121

EVALASTIC V / lightweight concrete

EVALASTIC V on insulation, mechanically fastened in lightweight concrete decking.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10210-111

EVALASTIC V / concrete

EVALASTIC V on insulation, mechanically fastened in steel concrete decking.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10120-161

EVALON VG / derived timber product

EVALON VG on EPS insulation, mechanically fastened in derived timber pannel.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10120-151

EVALON VG / timber deck

EVALON VG on EPS insulation, mechanically fastened in timber deck.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10120-141

EVALON VG / trapezoidal metal sheet

EVALON VG on EPS insulation, mechanically fastened in trapezoidal steel sheet profile.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10120-131

EVALON VG / pumice concrete pannels

EVALON VG on EPS insulation, mechanically fastened in pumice pannels.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10120-121

EVALON VG / lightweight concrete

EVALON VG on EPS insulation, mechanically fastened in lightweight concrete decking.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10120-111

EVALON VG / concrete

EVALON VG on EPS insulation, mechanically fastened in steel concrete decking.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

Detail 10240-061

EVALASTIC VGSK / derived timber product

EVALASTIC VGSK bonded on derived timber pannel

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10140-061

EVALON VGSK / derived timber product

EVALON VGSK bonded on derived timber product.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10240-231

EVALASTIC VGSK / pumice concrete pannels (ballasted)

EVALASTIC VGSK bonded on EPS insulation, supporting substructure pumice concrete pannels.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10240-211

EVALASTIC VGSK / concrete (ballasted)

EVALASTIC VGSK bonded on EPS insulation, supporting substructure steel concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10240-031

EVALASTIC VGSK / pumice concrete pannels

EVALASTIC VGSK bonded on EPS insulation, supporting substructure pumice concrete pannels.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10240-021

EVALASTIC VGSK / lightweight concrete

EVALASTIC VGSK bonded on EPS insulation, supporting substructure lightweight concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10140-231

EVALON VGSK / pumice concrete pannels (ballasted)

EVALON VGSK bonded on EPS insulation, supporting substructure pumice concrete pannels.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10140-221

EVALON VGSK / lightweight concrete (ballasted)

EVALON VGSK bonded on EPS insulation, supporting substructure lightweight concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10140-211

EVALON VGSK / concrete (ballasted)

EVALON VGSK bonded on EPS insulation, supporting substructure steel concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10240-011

EVALASTIC VGSK / concrete

EVALASTIC VGSK bonded on EPS insulation, supporting substructure steel concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10210-021

EVALASTIC V / lightweight concrete

EVALASTIC V bonded on insulation, supporting substructure lightweight concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10210-031

EVALASTIC V / pumice concrete pannels

EVALASTIC V bonded on insulation, supporting substructure pumice pannels.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10210-011

EVALASTIC V / concrete

EVALASTIC V bonded on insulation, supporting substructure steel concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10110-031

EVALON V / pumice concrete pannels

EVALON V bonded on insulation, supporting substructure pumice concrete pannels.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10110-021

EVALON V / lightweight concrete

EVALON V bonded on insulation, supporting substructure lightweight concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10110-011

EVALON V / concrete

EVALON V bonded on insulation, supporting substructure steel concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10140-031

EVALON VGSK / pumice concrete pannels

EVALON VGSK bonded on EPS insulation, supporting substructure pumice concrete pannels

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 1040-021

EVALON VGSK / lightweight concrete

EVALON VGSK bonded on EPS insulation, supporting substructure lightweight concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10130-031

EVALON VSK / pumice concrete pannels

EVALON VSK bonded on insulation, supporting substructure pumice concrete pannels.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 10130-021

EVALON VSK / lightweight concrete

EVALON VSK bonded on insulation, supporting substructure lightweight concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 40965-010

Cold roof / used + flexible

used cold roof, flexible connection

Categories: used roof, Wall flashing

Detail 40955-010

Cold roof / used + insulated

used cold roof, insulated connection

Categories: used roof, Wall flashing

Detail 40945-010

Cold roof / used

used cold roof, uninsulated connection

Categories: used roof, Wall flashing

Detail 40925-010

Warm roof / used + insulated

used warm roof, insulated connection

Categories: used roof, Wall flashing

Detail 40915-010

Warm roof / used

used warm roof, uninsulated connection

Categories: used roof, Wall flashing

Detail 40960-010

Cold roof / unused + flexible

unused cold roof, flexible connection

Categories: unused roof, Wall flashing

Detail 40950-010

Cold roof / unused + insulated

unused cold roof, insulated connection

Categories: unused roof, Wall flashing

Detail 40940-011

Cold roof / unused

unused cold roof, uninsulated connection

Categories: unused roof, Wall flashing

Detail 40930-010

Warm roof / unused + flexible

unused warm roof, flexible connection

Categories: unused roof, Wall flashing

Detail 40920-010

Warm roof / unused + insulated

unused warm roof, insulated connection

Categories: unused roof, Wall flashing

Detail 40910-010

Warm roof / unused

unused warm roof, uninsulated connection

Categories: unused roof, Wall flashing

EVALON VSK / concrete

EVALON VSK bonded on insulation, supporting substructure steel concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

EVALON VGSK geklebt auf EPS-Dämmung, Traguntergrund Stahlbetondecke

EVALON VGSK / concrete

EVALON VGSK bonded on EPS insulation, supporting substructure steel concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Cover Detail 10240-221

EVALASTIC VGSK / lightweight concrete (ballasted)

EVALASTIC VGSK bonded on EPS insulation, supporting substructure lightweight concrete decking.

Categories: adhered, Layer structure (membranes), unused roof area, unventilated roof (warm roof)

Detail 30920-711

Passive house / wall capping profiles

attic and roof edge for passive houses

Categories: Passive house (principle sketches), Special constructions

DIN 18234 / EVALON® dual

DIN 18234 – EVALON dual on insulation, mechanically fastened in trapezoidal metal sheet.

Categories: Layer structure

timber / EVALON® dual

EVALON® dual mechanically fastened in timber deck or derived timber pannel.

Categories:

concrete / EVALON® dual

EVALON® dual mechanically fastened incl.  thermal insulation made of polystyrol, mineral fibres or polyurethane. Vapour barrier or vapour retarder. Supporting substructure steel concrete decking.

Categories: Layer structure (membranes), mechanically fixed

trapezoidal steel sheet / EVALON® VG

EVALON VG mechanically fastened incl.  thermal insulation made of polystyrene. Vapour barrier or vapour retarder. Supporting substructure trapezoidal steel sheet Profile.

Categories: Layer structure (membranes), mechanically fixed

timber / EVALON® VG

EVALON VG mechanically fastened. Supporting substructure derived timber pannel.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, ventilated roof (cold roof)

concrete / EVALON® VG

EVALON VG mechanically fastened incl.  thermal insulation. Vapour barrier or vapour retarder. Supporting substructure steel concrete decking.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

timber / EVALON® VG

EVALON VG mechanically fastened. Supporting substructure derived timber pannel.

Categories: Layer structure (membranes), mechanically fixed, unused roof area, unventilated roof (warm roof)

trapezoidal steel sheet profile / EVALON® dual

EVALON® dual mechanically fastened incl.  thermal insulation made of polystyrol, mineral fibres or polyurethane. Vapour barrier or vapour retarder. Supporting substructure trapezoidal steel sheet profile.

Categories: Layer structure (membranes), mechanically fixed

timber / EVALON® dual

EVALON dual on insulation, mechanically fastened in timber deck.

Categories: Layer structure (membranes), mechanically fixed

Concrete Flat Roof Detail Drawings

Source: https://alwitra.de/en/flat-roof-details-search/

Posted by: patrickkilve1982.blogspot.com

0 Response to "Concrete Flat Roof Detail Drawings"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel